5: BSC 2780/3780 DLI Functions
DC 900-1340I 137
is limited to the size of the ICP message buffer minus the first 8 bytes of statistics). Refer
to Figure 5–3 for the format of the link trace data.
The time is reported in relative time in tenths of seconds. The clock starts at zero when
the Start Trace command is received. The time is a longword (4 bytes).
The line mode identifies whether the link is transmitting (0) or receiving (1).
The event reports the type of BSC control character sequence that was transmitted or
received. Ta ble 5 –7 lists the control sequences and the reported event number.
Figure 5–3: BSC 2780/3780 Link Trace Data Format
Byte 1
Byte 0
time
event line mode
data length
data